Page 42 - FireClass 2015-2016
P. 42
Panels
FireClass FC500
General Information
The EN54 certified FireClass 500 system is simple to install and easy to use.
Innovative software tools are provided to simplify all stages of a project from
system design to final commissioning,
The Fireclass 500 system’s large clear panel displays and optional real-time
graphics system provide the user with accurate information of fire and related
events. A high degree of flexibility across the Fireclass range makes it suitable
for a variety of small to medium size applications. Two versions are available
with 1 or 2 loops, with up to 250 devices per loop.
The ability to network (via RS485) up to 8 repeaters and up to 8 panels in
a master-slave network means that a single system can monitor up to 4000
sensors / devices. The availability of the EN54 certified FC500IP and
FC500PSTN communication modules allow sites to be easily and effectively
monitored, even from remote locations.
The on-board conventional zone feature of the panel plus additional addressable
conventional modules available on the loop, make the system suitable as
a replacement for older conventional installations without the need to replace all
the sensors.
General Features Product Order Codes
- EN54 certified. FC510 - 1 loop panel 557.200.721
- 1 or 2 loops. FC520 - 2 loop panel 557.200.722
- Up to 250 addresses on the loop. FC500REP Repeter 557.200.723
- Automatic drift compensation.
- 1 conventional zone.
- 64/128 programmable software zones.
- 16 programmable OC output (8 monitored).
- 1 Fire NAC output.
- 1 or 3 NAC outputs, monitored, silenceable and programmable.
- Fire and fault output relay.
- RS485 interface: up to 8 repeaters and 4 multi functional Interface.
- 4000 event log.
- PSTN phone dialer and IP module available.
FireClass FC500
General Information
The EN54 certified FireClass 500 system is simple to install and easy to use.
Innovative software tools are provided to simplify all stages of a project from
system design to final commissioning,
The Fireclass 500 system’s large clear panel displays and optional real-time
graphics system provide the user with accurate information of fire and related
events. A high degree of flexibility across the Fireclass range makes it suitable
for a variety of small to medium size applications. Two versions are available
with 1 or 2 loops, with up to 250 devices per loop.
The ability to network (via RS485) up to 8 repeaters and up to 8 panels in
a master-slave network means that a single system can monitor up to 4000
sensors / devices. The availability of the EN54 certified FC500IP and
FC500PSTN communication modules allow sites to be easily and effectively
monitored, even from remote locations.
The on-board conventional zone feature of the panel plus additional addressable
conventional modules available on the loop, make the system suitable as
a replacement for older conventional installations without the need to replace all
the sensors.
General Features Product Order Codes
- EN54 certified. FC510 - 1 loop panel 557.200.721
- 1 or 2 loops. FC520 - 2 loop panel 557.200.722
- Up to 250 addresses on the loop. FC500REP Repeter 557.200.723
- Automatic drift compensation.
- 1 conventional zone.
- 64/128 programmable software zones.
- 16 programmable OC output (8 monitored).
- 1 Fire NAC output.
- 1 or 3 NAC outputs, monitored, silenceable and programmable.
- Fire and fault output relay.
- RS485 interface: up to 8 repeaters and 4 multi functional Interface.
- 4000 event log.
- PSTN phone dialer and IP module available.